General Purpose Magnetic Flow Meter

 : WZ809087
 : ALMAGWP
 : Smart Measurements

Please verify all the details about the product. You can contact info@wizardengineering.co regarding product availability, pricing and delivery procedures.


Some products may run out of stock, but will be back in stock in a few days. Instant order and delivery options will be featured soon.


Technical data sheet
  General Purpose Magnetic Flow Meter - Datasheet

General Purpose Magnetic Flow Meter

Product Description

SMARTMEASUREMENT’s ALDPT-MV measures three separate process variables simultaneously and provides dynamic calculation of fully compensated mass flow rate for steam and liquids respectively and standard volume flow for gases. It measures differential pressure and absolute pressure from a single sensor and process temperature from a standard PT 100 Resistance Temperature Detector (RTD). Flow calculations include compensation of pressure and/or temperature as well as more complex variables such as discharge coefficient, thermal expansion, Reynolds number and compressibilty factor. The ALDPT-MV includes flow equations for steam, gases and liquids so that one model is all you need in your system. It can also measure static pressure with both integral or remote electronics and HART protocol. Many plants calculate mass flow in a host computer using a simplified mass flow equation. The ALPDT-MV provides full compensation of over 25 different parameters to achieve a 5x improvement in flow performance compared to uncompensated DP flow. The ALDPT-MV is ideally suited to work with SMC’s ACONE primary flow elements.

Requirements

  • Available in ⅜”~80″ (DN10~DN2000) line sizes
  • Wide fluid velocity range of 0-39 ft/sec (0-12 m/s) with excellent low-flow accuracy.
  • HART, RS485/Modbus Profibus-DP communications available
  • Easy-to-read OLED display; visible in low light environments and in direct sunlight, no backlighting necessary.
  • Optional IP68 enclosure; environmental protection class (submersible).
  • Various liner materials are available to satisfy nearly all industrial applications.
  • Excellent accuracy; ±0.5% of reading standard, ±0.2% of reading optional
  • Upright/reverse flowrate test function standard with every unit.
  • NIST traceable calibration certificate